Quantitative Determination of HABS Concentration in Surfactant Complex Systems induced by the excited UV absorption spectrometry
Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    研究并建立了准确检测多元复配驱油体系中重烷基苯磺酸盐(HABS)含量的方法。通过β-环糊精诱导HABS产生激发的紫外光谱信号检测水溶液体系中HABS的含量。结果表明,β-环糊精的诱导作用能显著提高HABS的检测精度,同时还能明显降低三采复配驱油剂中烷基酚聚氧乙烯醚(OP-10)、十二烷基磺酸钠(SDS)及聚丙烯酰胺(HPAM)等不同类型的常用组分对HABS定量产生的干扰。该方法检测HABS组分含量的检测精度为10-2~10-3mg/L,检测的最大误差为2.2%,驱油剂中各干扰组分对HABS的定量影响没有产生协同效应。

    Abstract:

    a new method was developed for the composition quantitative determination of heavy alkylbenzene sulfonate(HABS) in surfactant complex systems. The absorption spectra of HABS showed the presence of β-cyclodextrin (β-CD) could result in the enhancement of absorption intensities of HABS. The results indicated that the determination precision of HABS can be significantly improved by β-CD, and the effect of several common interfering substances (SDS,OP-10,HPAM,Cl-,Na+,Ca2+,etc.) on determination of HABS in β-CD aqueous solution can be greatly reduced. Based on this, the maximum errors of the determined HABS are less than 2.2% under multifactor interferences, and the precision of the method is as high as 10-2~10-3 mg/L. In general, synergistic effect of these interference factors could not formed by the excited UV absorption spectrometry.

    参考文献
    相似文献
    引证文献
引用本文

石东坡,尹先清,陈 武,付家新,任朝华,王任芳.采用激发光谱法准确检测复配体系中HABS浓度[J].油田化学,2014,31(2):303-306.
SHI Dong-Po, YIN Xian-Qing, CHEN Wu, FU Jia-Xin, REN Zhao-Hua, WANG Ren-Fang. Quantitative Determination of HABS Concentration in Surfactant Complex Systems induced by the excited UV absorption spectrometry[J]. OILFIELD CHEMISTRY,2014,31(2):303-306.

复制
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2014-09-03
  • 出版日期:
点击这里给我发消息

点击这里给我发消息